Experiment and analysis of comparison between standard vcrs & vcrs with ejector system

Show simple item record

dc.contributor.author Patel, Devarshi
dc.contributor.author Khare, Manjeet
dc.contributor.author Patel, Kunj
dc.contributor.author Parmar, Nirmesh
dc.contributor.author Patel, Krushit
dc.date.accessioned 2020-11-13T05:45:08Z
dc.date.available 2020-11-13T05:45:08Z
dc.date.issued 2019-04
dc.identifier.issn 2349-5162
dc.identifier.uri http://ir.paruluniversity.ac.in:8080/xmlui/handle/123456789/7841
dc.description.abstract As we know that an expansion device is used in standard vapor compression refrigeration system between the condenser and the evaporator, due to this there are losses to be found in expansion process that is loss in kinetic energy and can also drastically affects the COP of system , here we have used an ejector which helps in recovery of the available work and due to this there is increment found in the suction pressure of compressor which has aided in improvising the COP of the system . To compare and investigate the enhancement with normal system a model with refrigerant R22 was developed and temperature versus environment graph was measured using thermocouples at the system parameters, at specific points the properties of refrigerant undergoing a change of state was obtained from ASHRAE and the temperature data was recorded at normal room temperature conditions , from this study we can have obtained the results that a normal VCRS cycle with respect to an Ejector system shows more losses .The results obtained in the calculation clearly shows the rise in COP between 10-15% .This analysis pinpoints the performance of compressor as well as its necessity in the conventional VCRS cycle .Parametric analysis of the VCRS with ejector indicated that COP is affected directly by the temperatures of evaporator and condenser. Additionally the rise in compressor temperature due to on – off cycle was found to be lower with respect to former system. en_US
dc.language.iso en en_US
dc.publisher JETIR | Volume-6 | Issue-2 en_US
dc.subject Ejector, Vapor compression refrigeration system, COP, Household refrigerator, Hermetic reciprocating compressor, thermodynamic losses, PH diagram en_US
dc.title Experiment and analysis of comparison between standard vcrs & vcrs with ejector system en_US
dc.type Article en_US