Parul University Digital Repository

Analytical Method Development and Validation for Simultaneous Estimation of Cefixime and Azithromycin in Bulk and Their Combined Dosage Form

Show simple item record

dc.contributor.author Rokad, Jenisha
dc.date.accessioned 2020-11-30T09:58:24Z
dc.date.available 2020-11-30T09:58:24Z
dc.date.issued 2012
dc.identifier.uri http://ir.paruluniversity.ac.in:8080/xmlui/handle/123456789/8193
dc.description For Full Thesis Kindly contact to respective Library en_US
dc.description.abstract A simple, accurate and precise UV Spectrophotometric methods and RP-HPLC method was developed and validated for simultaneous estimation of Cefixime and Azithromycin in bulk and tablet dosage form. Two UV spectrophotometric methods were developed. In Q-absorption ratio method determination was carried out at 218 nm λmax of Azithromycin and 225 nm an Iso-bestic point of both the drug. The linearity range lies between 20-40 μg/ml for Cefixime and 50-100 μg/ml for Aithromycin at their respective wavelengths. Both the drugs were found in good agreement with the label claimed in the marketed formulation. In the tablets both the drugs were estimated as 100.2% and 97.84% Cefixime and Azithromycin respectively. While in another Absorption correction method Cefixime was estimated at 288 nm, at this wavelength Azithromycin show zero absorbance and no interference. For estimation of Azithromycin corrected absorbance was calculated at 220 nm due to the interference of Cefixime at this wavelength. Calibration curves were linear with correlation coefficient between 0.999 over the concentration range of 20-40 μg/ml and 50-100 μg/ml forCefixime and Azithromycin respectively. In the tablets both the drug were estimated as 100% and 99.96%, Cefixime and Azithromycin respectively. The RP-HPLC method for simultaneous estimation of Cefixime and Azithromycin. The separation was achieved on a Phenomenex luna ODS C18 (250mm X 4.6 mm i.d., 5 μm particle size) with an isocratic mixture of acetonitrile: methanol: 1N NaOH: 80mM phosphate buffer pH 5.6 adjusted with glacial ortho-phosphoric acid in the ratio of 30:15:2.5:52.5 v/v. The mobile phase at a flow rate of 1.0 ml/min, Injection volume 20μl and wavelength of detection was kept at 215 nm. The retention time Cefixim and Azithromycin was 2.41±0.1min and 3.977±0.1min, respectively. The linearity of a simple, accurate, precise RP-HPLC method was developed and validated for simultaneous estimation of Cefixime and Azithromycin in bulk and tablet dosage form. The proposed method was investigated in the range of 20-80 μg/ml and 50-200 μg/ml for Cefixime and Azithromycin, respectively. Correlation coefficient was 0.9995 and 0.999 for Cefixime and Azithromycin, respectively. The limit of detection was 0.432 μg/ml and 0.769 μg/ml for Cefixime and Azithromycin, respectively and the limit of quantification was 1.296 μg/ml and 2.307 μg/ml for Cefixime and Azithromycin, respectively. en_US
dc.language.iso en en_US
dc.publisher Parul University en_US
dc.subject Cefixime en_US
dc.subject Azithromycine en_US
dc.subject UV Spectroscopic method en_US
dc.subject Absorption correction method en_US
dc.subject Q-Abasorption ratio method and RP-HPLC en_US
dc.title Analytical Method Development and Validation for Simultaneous Estimation of Cefixime and Azithromycin in Bulk and Their Combined Dosage Form en_US
dc.title.alternative 102140804003 en_US
dc.type Thesis en_US