Abstract:
Mast tower are generally tall structures, self-supporting structures and in engineering
terms cantilever structures, which are designed to support the high-tension wires,
testing the other towers and so on.
Further to the parametric study on structural behavior of masts, basic parameters are
studied, like axial, compression and tension capacity of the members, deflection
behavior etc.
The analysis of the tower testing high mast is carried out in different ways, mainly
governs under high tensions due to testing and wind action on exposed area. These
mast towers are generally used at tower testing stations. Two masts present to test a
tower, one of them is Longitudinal Mast and other one is Transverse Mast. These
masts have numbers of columns and beams according to size of tower beds, which are
to be tested.
In the analysis, the tower model firstly fixed and then wind pressure applied to the
exposed area of the mast. Wind force is the computed with IS875: part-III, in which
different categories factors are used according to mast height, locations and other ones.
The design of the tower is done with IS:802 part-1/sec-2 & part-2.
The applications of the mast towers are at each testing stations for testing 132kV to
1200kV gantry, transmission line towers and for reviewing the same.