dc.description For Full Thesis Kindly contact to respective Library en_US
dc.description.abstract A simple, accurate and precise UV spectrophotometric methods and RP-HPLC method was developed and validated for simultaneous estimation of acetaminophen and pamabrom in bulk and tablet dosage form. In simultaneous equation method determination was carried out at 242.8 nm λmax of Acetaminophen and 279 nm λmax of pamabrom. The linearity range lies between 3.25-19.5 μg/ml for acetaminophen and 0.25-1.75 μg/ml for pamabrom at their respective wavelengths. Both the drugs were found in good agreement with the label claimed in the marketed formulation. In the tablets both the drugs were estimated as 97.24% and 102.11% Acetaminophen and Pamabrom respectively. Calibration curves were linear with correlation coefficient 0.999 and 0.998 over the concentration range of 3.75-19.5 μg/ml and 0.25-1.75 μg/ml for Acetaminophen and Pamabrom respectively. The RP-HPLC method for simultaneous estimation of Acetaminophen and Pamabrom was developed. The separation was achieved on a Phenomenex luna ODS C18 (250mm X 4.6 mm i.d., 5 μm particle size) with an isocratic mixture of Methanol:Water (50:50) pH-3.0. The mobile phase at a flow rate of 1.0 ml/min, Injection volume 20μl and wavelength of detection was kept at 265 nm. The retention time of Acetaminophen and Pamabrom was 2.9±0.2min and 4.8±0.2min respectively. The linearity of a simple, accurate, precise RP-HPLC method was developed and validated for simultaneous estimation of Acetaminophen and Pamabrom in bulk and tablet dosage form. The proposed method was investigated in the range of 3.25-19.5μg/ml and 0.25-1.5μg/ml for Acetaminophen and Pamabrom, respectively. Correlation coefficient was 0.998 and 0.998 for Acetaminophen and Pamabrom, respectively. The limit of detection was 0.222μg/ml and 0.055μg/ml for Acetaminophen and Pamabrom respectively and the limit of quantification was 0.673μg/ml and 0.169μg/ml for Acetaminophen and Pamabrom, respectively. en_US
dc.language.iso en en_US
dc.publisher Parul University en_US
dc.subject 112140813018 en_US
dc.title Development and validation of analytical methods for simulation estimation of acetaminophen and pamabrom in bulk and in tablet dosage form en_US
dc.title.alternative 112140813018 en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account