Abstract:
The present work involves the development and validation of a simple, accurate and
precise U.V spectrophotometric method, RP-HPLC and Forced Degradation Study
Method for the assay of Triamterene and Furosemide. Simple, specific, accurate,
precise and reproducible method have been developed and validated for the
simultaneous estimation of both drugs in their combined dosage form. UVspectrophotometric
method was a determination using the derivative
spectrophotometry at 268 nm and 328 nm over the concentration range 2-12 μg/ml
and 4-14 μg/ml for Triamterene and Furosemide in methanol respectively. The %
recoveries of the both the drugs were found to be 99.56-101.07% and 99.11-100.85%
respectively. The Stability Indicating RP-HPLC method has shown adequate
separation of Triamterene and Furosemide in its tablet dosage Form. The separation
was achieved on a Enable C18 H(250mm X 4.6 mm i.d., 5 μm particle size) with a
isocratic system of 0.1% Formic Acid in Water : Acetonitrile(65:35%v/v) the mobile
phase at a flow rate of 0.8 ml/min, Injection volume 10μl and wavelength of detection
used was 274nm. The retention time for Triamterene and Furosemide was obtained as 1.948±0.1min and3.753 ±0.1min, respectively. The linearity of the proposed method
was investigated in the range of 8-12 μg/ml and 6.4-9.6 μg/ml and coefficient was
0.999 and 0.994 for Triamterene and Furosemide, respectively. The developed
method was validated as per ICH guideline and the results were found to be
satisfactory, thus the method is specific, rapid and simple with good sensitivity for
estimation of Triamterene and Furosemide